User manual

Mask Testing
R&S
®
RTO
226User Manual 1316.0827.02 ─ 06
Definition type
Sets the method of mask definition.
"User"
The mask is created manually by tapping the mask points on the touch
screen and/or by entering the numerical x- and y-values of the mask
points.
"Waveform"
The mask is created from an existing waveform. The envelope of the
waveform builds the upper and lower limit line of the mask, and the limits
are moved and stretched. The result is a tolerance tube around the
waveform that is used as mask.
SCPI command:
MTESt:CTYPe on page 599
Fail condition, Violation tolerance
The fail criteria for a mask test is set by two parameters: "Fail condition" and "Violation
tolerance".
"Fail condition" defines the kind of hits to be considered for test evaluation:
"Samples": Considers the number of samples that hit the mask.
"Acquisitions": Considers the number of acquisitions that contain at least one sample
hit. How many samples hit the mask in that acquisition is not relevant.
"Violation tolerance" sets the number of tolerable sample hits or acquisition hits.
A test has failed if the number of sample hits or acquisition hits exceeds the limit of vio-
lation tolerance hits.
Example:
The example test has failed when the sixth acquisition violated the mask.
SCPI command:
MTESt:CONDition on page 599
MTESt:TOLerance on page 599
Save / load mask test
Provides all functions to store and recall a mask test. The mask definition, defined actions
and fail conditions are stored in an R&S RTO-specific xml file.
"Load, Save"
Recalls or stores the specified file.
"Open, Save
As"
Opens a dialog box where you can select the directory the file name.
See also: chapter 12.2.4, "File Selection Dialog", on page 355.
"Delete"
Opens a dialog box where you can select the file to be deleted.