User manual

Measurements
R&S
®
RTO
127User Manual 1316.0827.02 ─ 06
Show in all diagrams
Shows the enabled cursor measurements in all active diagrams of the same (time/spec-
trum) domain.
5.1.3.2 Cursor Style and Label Tab
The settings in this tab configure the display of the cursors.
C1/C2/C3/C4
The settings for each of the four available cursor measurements are configured on sep-
arate tabs. For each measurement, labels can be defined for the cursors. By default, the
cursors are labeled as C1.1, C1.2, C2.1, C2.2, C3.1, C3.2, C4.1, C4.2.
Vertical cursor 1/2
Defines a label to be displayed with the vertical cursors.
Horizontal cursor 1/2
Defines a label to be displayed with the horizontal cursors.
Show label
Shows the cursor labels in the diagram.
Cursor style
Defines how the cursor is displayed in the diagram.
"Lines"
The cursors are displayed as lines.
"Line & Rhom-
bus"
The cursors are displayed as lines. The intersections of the cursors with
the waveforms are displayed by rhombus-shaped points.
"Rhombus"
The intersections of the cursors with the waveforms are displayed by
rhombus-shaped points.
5.1.3.3 Peak Search Tab
The settings on this tab are only available in spectrum mode, i.e. if FFT analysis is
selected for a math waveform which is used as the source of the cursor measurement.
In this case, the cursors can indicate the results of a peak search on the waveform.
Cursor measurements