Instruction Manual

3
counter clockwise 1/2 to 3/4 of a turn, or until you hear or see water
owing through the valve. To turn the water off, turn the solenoid
clockwise 1/2 to 3/4 of a turn and wait a few seconds for the
valve to close.
8. Program the 410BT series controller (see pages 4-12).
6. IN
-
LINE VALVE INSTALLATION
Rated operating pressure: 10-125 PSI
Recommended Operating Pressure: 10-80 PSI
Warning: Wrap all ttings with Teon tape! Do not use pipe cement on
ttings or the valve as this will damage the valve and void the warranty!
1. Shut off main water supply.
2. Install a 3/4 ball or gate valve onto the PVC pipe or to the valve
manifold before installing the controller (Figure 6a and 6b).
CHART A
Model Compatible Valves
30
-
920
BERMAD series 200, HIT series 500,DOROT series 80,
GRISWOLD series2000, DW and BUCKNER series VB valves
30
-
921
INCLUDED
RAIN BIRD DV, DVF, PGA, PEB
(
1 only
)
, GB, EFB
-
C P,
BPE, PESB
(
1 only
)
and ASVF valves
30
-
922
INCLUDED
HUNTER series ASV, HPV, ICV,PGV, SRV, IBV and
ASVF valves
30
-
923
WEATHERMATIC series 12000, 21000, 8200CR valves
30
-
924
INCLUDED
IRRITROL series 100, 200B, 205, 217B,
700, 2400, 2500, 2600 and TORO series 220, P220 valves
30
-
925
SUPERIOR series 950, HUNTER HBV and TORO series
252 valves
(
1.5 and larger
)