Specifications

141
10.3 Control register: checks and due dates
NOTE
At the end of the manual you will  nd a few pages where you can  ll in these registers.
Controls Notes
Mandatory controls that must be made at 0 hours at the  rst
installation of the equipment
Closure due to door gravity during ascent/descent (on baskets) o
Control of the machine / equipment for the presence and state of
preservation safety Decals
o
Control of the machine \ equipment for the presence and state of
preservation of Bearing capacity diagrams
o
Control of the machine \ equipment for the presence and state of
preservation of Use and maintenance manual
o
Control of the machine \ equipment for the presence and state of
preservation of Nameplates
o
Ascent/descent limit switches (if present) o
Load fastening hook (if present) o
Load limiter (if present) o
Pull limiter (if present) o
Front infeed micro switch closed (if present) o
Micro switch for detecting the locking pins (if present) o
Maximum hydraulic plant pressure (if present) o
Emergency stop button (on baskets) o
Hooking points for safety harnesses (on baskets) o
Anti-collision sensors (if present) o
Spirit level calibration (if present) o
Extensimeter transducer (if present) o
Shut-off valve (if present) o
Load check valve (if present) o
Checking the compliance of machine work area with the equipment
installed
o
Checking the compliance of machine operating mode with the
equipment installed
o
Checking the operation and integrity of electrical connections and
circuits
o
Check general integrity and state of wear of the equipment (framework,
cables, hooks, chains, ropes, hydraulic pipes, electric cables, end run,
transducers, strain gauges, radio-control)
o
Mandatory controls that must be made every 250 hours or
every 2 months
Control of the machine / equipment for the presence and state of
preservation safety Decals
o
Control of the machine \ equipment for the presence and state of
preservation of Bearing capacity diagrams
o