7.4.2 Electric connection procedure
The electric connections at the head of the boom can be
with 6 or 24 poles, but the connection procedure remains
unvaried for both.
Perform the following operations for the equipment supplied
with electric plant:
- Perform the equipment installation procedures described
previously.
- Switch the vehicle off .
- Disconnect the plug from the boom socket (Fig. 1-I0300,
pos. 1) lowering the 2 safety levers (Fig. 1-I0300, pos. 2).
- Shift the plug positioned on the boom socket in the false
socket positioned at the side (Fig. 2-I0300) and fi x it using
the relevant levers.
- Disconnect the plug from the false socket on the
equipment (Fig. 3-I0300, pos. 1) lowering the 2 safety
levers (Fig. 3-I0300, pos. 2).
- Connect the equipment plug to the boom electric socket,
fi xing it by lifting the 2 safety levers (Fig. 4-I0300, pos. 1).
- Once the equipment has been fi xed correctly, turn the
vehicle on and set the correct work mode of the same,
relative to the equipment just installed. Consult the
“Equipment and operational mode selection” chapter in
the vehicle use and maintenance manual.
- Check that the capacity diagram relative to the vehicle and
the equipment just installed is present in the cab.