Specifications

107
7.3.5 Flat-Face couplings connection
To connect the Flat-Face quick couplings:
1. Perform the equipment installation procedures
described in the “Equipment installation procedure”:
2. Switch the vehicle off .
3. In the event of closed-centre distributor, discharge the
residual pressure from the plant as described previously.
4. Remove any dirt from the plug and socket.
5. Place the plug at the centre of the socket and push the
plug fully home (Fig. 11-I0200), until the socket ring has
lifted.
6. Turn the ring to block the plug in the socket (Fig. 12-
I0200).
7. Check that the hydraulic hose is fi xed correctly.
8. Carry out the same operations for both hoses.
Consult the equipment manual to check the
correct operation of the same.
10- I0200
11- I0200
12- I0200