Operating instructions

91500 Revision B
14 DiCon Fiberoptics VX500 Fiberoptic Switch
To select the output channel of a 2
×
N blocking switch with up to 16 output channels, set the
five channel address inputs (<D4:D0>) and the RESET input as indicated in Table 5, then
strobe the device.
Maintaining Channel Position
To maintain channel position, keep the STROBE signal high and do not interrupt supply
power.
Table 5:
Control Codes For 2
×
N Blocking Configurations
RESET D4 D3 D2 D1 D0
Common 1
Output Channel
Common 2
Output Channel
0xxxxx0 reset -1 reset
1000001 0 block
100001block 1
1000102 block
100011block 2
1001003 block
100101block 3
1001104 block
100111block 4
1010005 block
101001block 5
1010106 block
101011block 6
1011007 block
101101block 7
1011108 block
101111block 8
1100009 block
110001block 9
11001010 block
110011block 10
11010011 block
110101block 11
11011012 block
110111block 12
11100013 block
111001block 13
11101014 block
111011block 14
11110015 block
111101block 15
11111016 block
111111block 16