Control current cable CY 12 x 0.75 mm²
maximum length 4 meters. Power cable 5 x
2.5 mm² YMVK or a ground cable 4 x 2.5 mm²
YMVK-AS. Also for a 3.7 kW model it is preferable
to install a cable with a 3 Phase neutral and earth.
Mounting the control box.
3 IMPLEMENTING
Connect the supply cable of the built-in charging station behind a separate circuit
breaker and a 16 Ampere earth leakage circuit breaker which is used exclusively for
the charging station.
When using an 11 kW model for a Renault Zoe, use a type B or EV earth leakage circuit
breaker. Mount the control box within a distance of max. 4 metres from the built-in
charging station. Connect the power cable to terminals L1, L2, L3, N and earth. With a
230 V 3.7 kW version, L2 and L3 remain free.
Connect the power cable with L1, L2, L3, N which is connected to the charging station
directly to the relays. The Zero is on the right side of the Phase wires. Then connect
the control current cable:
Photo 4 - Mounting the
control box
Terminal Wire colour Description
1 purple Cp
2 pink Cp
3 yellow Pp
4 red Locking mechanism
5 white Locking mechanism
6 blue Locking mechanism