Instructions

www.diclaadsystemen.nl
30
NL
DE
EN
9 CONNECTING SEVERAL CHARGING STATIONS
Use a shielded cable, at least 3 x 0.8 mm², to connect the charging stations.
Only the Master and Slave End have the resistors mounted.
Connect up to 7 charging stations to the master. With 2 coupled
charging stations, the resistors remain mounted.
!
Remove resistance
If using a slave model,
remove the resistance
between terminals 1 and 2
GSM GPS connectors
Remove from the slave and
slave end models with a spanner
8 the GSM GPS connectors from
the EVC module. The antenna
of the master takes care of the
online connection.
R
Master
Slave12 12 12Slave end
R
GND
Distribution through: inter BÄR GmbH + Co. KG • Hälverstraße 43, 58579 Schalksmühle,