Instructions
www.diclaadsystemen.nl
19
NL
DE
EN
NL
DE
EN
The charger is not equipped with a main power protection, mount it externally in for
example a group box. Use your own protection for the charging point. The charging
point is set to 16 ampere payload.
Lights on the charge point:
Green: Power • Blue: Charge
3a ADJUST TO 10 A
The BlackBoxx is adjusted to charge 16 A by default. When 10 A charging is desired,
connect the black wire 10 A to the yellow / green ground terminal.
4 IMPLEMENTING
Has the cable been correctly connected and checked for short circuits? If the charger
is properly connected, switch on protection 5HS3. The green “Power” LED will light
up when the external protection is switched on. Now use the EV-tester to test the
charging point for operation. This tester is available from your supplier.
5 USE CHARGING STATION
Start loading: Plug and charge output
In a Plug and Charge output, the charger switches on automatically when the car
is connected to the charging station. That type 2 Mennekes connector is automati-
cally locked.
• The green “power” LED lights up: the charger is ready to charge or your
battery is full.
• The blue “Charge” LED lights up: the charger charges
Attention! Start charging by first connecting your
vehicle to the charging point. After connection,
check the charging point for a correct connec-
tion. After the check, the charger starts and the
blue “Charge” LED lights up.
When the battery is fully charged, the charger
automatically stops charging, the green Power
LAADPAS
LAADPAS
LAADPAS