CAMERA INTERFACE S3C2450X RISC MICROPROCESSOR
23-10
4.5 TIMING DIAGRAM FOR REGISTER SETTING
The first register setting for frame capture command can be occurred in anywhere of frame period. But, it is
recommend to do first setting at the VSYNC ā€œLā€ state. VSYNC information can be read from status SFR. Refer to
the below figure. All command include ImgCptEn, is valid at VSYNC falling edge. Be sure that except first SFR
setting, all command should be programmed in ISR(Interrupt Service Routine). It is not allowed for target size
information to be changed during capture operation. However, image mirror or rotation, windowing, and Zoom In
settings are allowed to change in capturing operation. but, In case preview path select MSDMA input mode, all
command should be programmed after MSDMA and Preview DMA operation end.