HSMMC CONTROLLER S3C2450X RISC MICROPROCESSOR
21-70
5.32 FORCE EVENT REGISTER FOR ERROR INTERRUPT STATUS
Register Address R/W Description Reset Value
FEERR0 0X4AC00052 WO Force Event Error Interrupt Register Error Interrupt
(Channel 0)
0x0000
FEERR1 0X4A800052 WO Force Event Error Interrupt Register Error Interrupt
(Channel 1)
0x0000
The Force Event Register is not a physically implemented register. Rather, it is an address at which the Error
Interrupt Status register can be written. The effect of a write to this address will be reflected in the Error Interrupt
Status Register if the corresponding bit of the Error Interrupt Status Enable Register is set.
Writing 1: set each bit of the Error Interrupt Status Register
Writing 0: no effect
Note: By setting this register, the Error Interrupt can be set in the Error Interrupt Status register. In order to generate
interrupt signal, both the Error Interrupt Status Enable and Error Interrupt Signal Enable shall be set.
Name Bit Description Initial Value
[15:10] Reserved 0x0
[9]
Force Event for ADMA Error
1 = Interrupt is generated
0 = No Interrupt
0
[8]
Force Event for Auto CMD12 Error
1 = Interrupt is generated
0 = No Interrupt
0
[7] Reserved 0
[6]
Force Event for Data End Bit Error
1 = Interrupt is generated
0 = No Interrupt
0
[5]
Force Event for Data CRC Error
1 = Interrupt is generated
0 = No Interrupt
0
[4]
Force Event for Data Timeout Error
1 = Interrupt is generated
0 = No Interrupt
0
[3]
Force Event for Command Index Error
1 = Interrupt is generated
0 = No Interrupt
0
[2]
Force Event for Command End Bit Error
1 = Interrupt is generated
0 = No Interrupt
0
[1]
Force Event for Command CRC Error
1 = Interrupt is generated
0 = No Interrupt
0
[0]
Force Event for Command Timeout Error
1 = Interrupt is generated
0 = No Interrupt
0