User's Manual

Table Of Contents
S3C2450X RISC MICROPROCESSOR I/O PORTS
11-37
EXTINT1 Bit Description
Reserved [31] Reserved
EINT15 [30:28] Setting the signaling method of the EINT15.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
Reserved [27] Filter enable for EINT14
0 = Filter Enable 1 = Filter Disable
EINT14 [26:24] Setting the signaling method of the EINT14.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
Reserved [23] Reserved
EINT13 [22:20] Setting the signaling method of the EINT13.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
Reserved [19] Reserved
EINT12 [18:16] Setting the signaling method of the EINT12.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
Reserved [15] Reserved
EINT11 [14:12] Setting the signaling method of the EINT11.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
Reserved [11] Reserved
EINT10 [10:8] Setting the signaling method of the EINT10.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
Reserved [7] Reserved
EINT9 [6:4] Setting the signaling method of the EINT9.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
Reserved [3] Reserved
EINT8 [2:0] Setting the signaling method of the EINT8.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered