I/O PORTS S3C2450X RISC MICROPROCESSOR
11-36
EXTINT0 Bit Description
EINT3 [14:12] Setting the signalling method of the EINT3.
000 = Low level
001 = High level
01x = Falling edge triggered
10x = Rising edge triggered
11x = Both edge triggered
Reserved [11] Reserved
EINT2 [10:8] Setting the signalling method of the EINT2.
000 = Low level
001 = High level
01x = Falling edge triggered
10x = Rising edge triggered
11x = Both edge triggered
Reserved [7] Reserved
EINT1 [6:4] Setting the signalling method of the EINT1.
000 = Low level
001 = High level
01x = Falling edge triggered
10x = Rising edge triggered
11x = Both edge triggered
Reserved [3] Reserved
EINT0 [2:0] Setting the signalling method of the EINT0.
000 = Low level
001 = High level
01x = Falling edge triggered
10x = Rising edge triggered
11x = Both edge triggered