Specifications

UPGRADING FIRMWARE
120 Reference Edition 1.08 CXPS Manual
4 Open the 10/100T Network Connection between the control computer and the FTP
Server within the CXPS by typing in the commands:
open <ip address>
User: bdv
Password: blackdiamond
A prompt sign appears: >
5 To switch to binary mode, type the command: bin
A command prompt appears again: >
6 Type the command: put <filename>, where the file name is the name of the file you
downloaded in Step 2 of “Download or Copy Firmware Upgrade to the Control
Computer.”
In our example, the command is: put bdvcxps.bin.xxx
7 Close the connection to the CXPS ftp server by typing the command: quit
The connection to the CXPS ftp server is closed.
8 Open a Telnet session with the CXPS by typing the command: telnet <ipaddr>
8998
The Telnet session is initiated.
9 Enter the network password.
The default password is “blackdiamond”.
10 Issue the upgrade firmware command in one of two ways:
a
From the serial port terminal, issue the RS-232 command: ufw
Progress information about the upgrade process appears on the terminal.
b From the Ethernet connection Command Prompt, type in the command: ufw
11 The upgrade process takes approximately 2 - 3 minutes. When the upgrade is done,
you are instructed to power cycle the CXPS.
12 Type the command: rfd
Once you have issued this command, the firmware upgrade is complete, unless you are using
firmware version 4.85 or previous.
13 If you are using firmware version 4.85 or previous, type the command: rstoutputattr
Once you have issued this command, the firmware upgrade is complete.
NOTE:
If the IP address is not known, establish RS-232 control of the CXPS and
issue the SHOWNET command. This returns the IP address of the device.