Specifications

. . . . .
RS-232 AND 10/100T PROTOCOL
CXPS Command Set
CXPS Manual Edition 1.08 Reference 107
NEWEDID NEDID <INPUT #> <hfp> <hs>
<hbp> <hact> <vfp> <vs>
<vbp> <vact> <hfreq> <sync>
<phase> <vpol> <hpol>
<interlace>
Creates a special EDID timing for the designated
input, with the specified parameters.
<hfreq> in Hz.
<sync> is 3,4, or 5 wire.
<vpol> is vertical sync polarity; 1 = positive, 0 =
negative.
<hpol> is horizontal sync polarity.
<interlace> is 1 = interlaced, 0 = non-
interlaced.
NOTE: Before issuing this command, disconnect
the input from the source.
OUTPUTPOWER OUTP <output #> <ON|OFF> Turns the output’s phantom power on or off.
PROGALLEDID PROGALLEDID <DL|SL> Programs all inputs with the factory-default dual-
link or single-link EDID value.
PROGEDID PROGEDID <input #> <DL|SL> Programs the default dual link or single link EDID
value to the selected input channel. NOTE: Before
issuing this command, disconnect the input from
the source.
PROGJUPEDID PROGJUPEDID <input #> Allows you to program the Cyviz-xpo3 50 Hz
EDID data to the specified input of the CXPS.
NOTE: Before issuing this command, disconnect
the input from the source.
PROGSRXEDID PROGSRXEDID <input #> Allows you to program the SONY SRX projector’s
EDID data to the specified input of the CXPS.
NOTE: Before issuing this command, disconnect
the input from the source.
PROGXPOEDID PROGXPOEDID <input #> Allows you to program the Cyviz-xpo3 EDID data
to the specified input of the CXPS. NOTE: Before
issuing this command, disconnect the input from
the source.
RDINEDID RDINEDID <input #> Returns the EDID data on the selected input
channel. NOTE: Before issuing this command,
disconnect the input from the source.
REMAP REMAP <ON|OFF> Turns renumbering of I/O cards ON or OFF.
When ON, remap will automatically adjust the
numbering of all input and output channels to be in
consecutive order. If a card is added or removed,
the channel numbers will adjust to accommodate
the addition.
When remap is OFF, input and output channel
numbers will be determined by the slot their card
occupies, and I/O channel numbers will not be
readjusted if cards are added or removed.
Default is ON.
RESET RST Initiates a system reset of the CXPS.
SYSTEM COMMANDS
Command Syntax Action
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .