By default, the Dialogic Configuration Manager for software version SR5.01.2
sets the parameter PBXSwitch type to Nortel_Norstar. This parameter must be
changed to the appropriate PBX type you are integrating with OneBox. Follow
these steps to change the parameter for each D/82JCT-U linecard installed:
1. Click Start, point to Programs, point to Dialogic System Software, and
select Dialogic Configuration Manager-DCM.
2. Stop the Dialogic service if it is running.
3. Double-click the installed D/82U linecard to open the Properties sheet.
4. On the Miscellaneous tab, select the PBXSwitch parameter.
5. In the Values list, select MITEL_DNIC_M430 as the PBXSwitch type.
6. On the Telephony Bus tab, verify that the correct PCM encoding scheme is
selected. The default value is automatic or U-Law; you must change this
value to A-Law outside of the U.S. and Japan.
7. Click OK.
8. Repeat steps 3-7 for each D/82 linecard that is installed.
9. Restart the Dialogic service and close Dialogic Configuration Manager.