Programming instructions

Integration Technical Note 9
MITEL D/82 Station Set Emulation ©June 2003 Ericsson Enterprise AB
EN/LZT 108 6655 R1A
Programming the SX-2000 System with MS2006 (M23.2) and Higher Software
This section explains how to program a MITEL SX-2000 telephone system with
MS2006 (M23.2) and higher software. The installing technician should be familiar
with programming this telephone system. For detailed programming information
on the MITEL SX-2000, refer to the manuals that accompanied the telephone
system.
Programming the DNIC Ports for OneBox
DNI Assignment Programming
Program all the OneBox DNIC ports in the DNI Assignment Program Channel
1 as “Superset 430”. Leave Channel 2 blank.
Multi-line Set Programming
Program all required DNIC ports in the Multi-line Set Assignment Form
[MU S A]. Set the ACD Agent field to No with the Call Announce field blank.
Programming the Hunt Group
In Group Forms, select Hunt Group Assignment Form [HU] and set up a
circular hunt group with the DNIC ports used with OneBox. Choose an easily
remembered number; subscribers will use this number to call OneBox.
1. Enter a pilot number for the hunt group, then press RECALL.
2. Define the hunt mode as circular.
3. Define the hunt group type as follows:
On MS2007 (Lightware 27, N-Stream, or higher), specify Voicemail.
On all other software versions, specify Voice.
4. Assign all of the integrated extension numbers as members of the hunt
group, in ascending order.
5. In the Call Rerouting First Alternative Assignment Form [CAL R F], assign
an overflow position for the hunt group.
6. In the Call Rerouting Assignment Form [CAL R AS], assign the Alternative
number (from the above step) to the hunt group to be invoked when all
DNIC ports are busy.