User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 308
Dialogic Corporation
Resolved IPY00015228 31100 -- DMV160LPHIZ The functions cl_StartTrace( ), cl_StopTrace( ) and
cl_DecodeTrace( ) are not supported on Dialogic
®
Analog HiZ boards. If the buttons to “Start Trace”,
“Stop Trace” or “Decode Trace” are selected from the
Sniffer menu bar of the SnifferMFC demo while
running with the Dialogic
®
DMV160LPHIZ Board, error
code “0x3006 function not supported” will be returned.
This information will be added to the Dialogic
®
Call
Logging API Software Reference.
Resolved IPY00015226 31072 -- DMV160LPHIZ In the SnifferMFC.EXE, the ability to select TSC as an
argument for cl_Open( ) was omitted. The problem
can be resolved by recompiling SnifferMFC from
source.
Resolved IPY00015217 30280 -- DMV160LPHIZ Fax tones can't be reliably detected if PVD and PAMD
detection are disabled while call analysis is enabled.
To ensure that fax tones can be detected for call
analysis, make sure that PVD and PAMD are enabled.
Resolved IPY00011464 30206 -- DMV160LPHIZ Collection of dialed digits is not supported for
outbound calls.
Resolved IPY00008173 30959 -- DMV160LPHIZ The cl_GetMessageDetails( ) function returns an
“<unknown>” message text for the pszName instead
of displaying the proper message text in the cases of
“CallInfo_CallerName” and “CallInfo_DateTime”. This
issue pertains to Dialogic
®
Analog HiZ Boards only.
Resolved IPY00036280 -- 142 Fax When a Dialogic
®
VFX/41JCT-LS Board is receiving
fax when the line quality is not good, sometimes the
calls are terminated by error with ESTAT 193.
Resolved IPY00034495 -- 131 Fax Firmware crash occurs when certain TIFF file is sent
from one channel in MH, 9600 MSLT=10ms condition.
Resolved IPY00034105 -- 125 Fax Dialogic
®
VFX/41JCT-LS Board channel is unable to
send/receive fax after particular fax call scenario
occurs.
Resolved IPY00031534 -- 139 Fax When sending a fax, the Dialogic
®
VFX/41JCT-LS
Board cannot establish phase B with some particular
fax machine.
Resolved IPY00010370 34054 27 GDK GDK functionality is not operational. GDK channels
cannot be detected.
Resolved IPY00036418 -- 139 Global Call On Dialogic
®
DM3 Boards, the gc_Open( ) function
does not cause sabmr messages to be sent for the
DPNSS protocol.
Resolved IPY00034841 -- 134 Global Call While closing the H.323 channels, some may be stuck
in an intermediate state causing the subsequent
events to be directed to incorrect devices.
Resolved IPY00032263 36681 92 Global Call The gc_SetupTransfer( ) function fails when calling
far end, ring no answer.
Resolved IPY00032022 55549 -- Global Call Incorrect cause returned for event GCEV_BLOCKED.
Table 9. Issues Sorted By Type, Dialogic
®
System Release 6.0 PCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description