Installation
This chapter provides information about installing and initially logging on to the Dialogic
®
1000
Media Gateway (DMG1000) and Dialogic
®
2000 Media Gateway (DMG2000) models in the
following sections:
Installation Procedure - DMG1000 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Installation Procedure - DMG2000 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Basic Configuration via the Serial Port (All Models) . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Basic Configuration via the IP Interface (All Models) . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.1 Installation Procedure - DMG1000 Models
Perform the following steps to install the DMG1000 system for use as a phone emulator (connected
to PBX):
1. Connect the 10/100BaseT Ethernet cable from the LAN connector on the rear panel of the
DMG1000 to the Ethernet. See Section 1.2, “Rear Panel Controls, Indicators, and Connectors
for DMG1000 Models”, on page 17 for descriptions of the rear panel connectors.
2. For a digital DMG1000, connect up to eight digital PBX lines from the digital PBX to the
eight PBX Port connectors on the rear panel of the DMG1000. (See the User’s Guide for more
details.)
For an analog DMG1000, connect up to eight analog PBX lines from the analog PBX to the
eight PBX Port connectors on the rear panel of the DMG1000.
To connect a port on the DMG1000 to the associated PBX port, a PBX-to-DMG1000 cable is
needed. This requires an 8-wire cable with an 8-pin modular plug on one end and a connector
on the other end that is determined by the mating connector on the PBX.
The DMG1000 is connected to the PBX as follows:
a. Connect the 8-pin modular plug end of a PBX-to-DMG1000 cable to PBX PORT
connector 1 on the rear panel of the DMG1000.
b. Connect the other end of the PBX-to-DMG1000 cable to a telephone port on the PBX.
c. Repeat steps 1 and 2 for each successive PBX port that is to be connected to the
DMG1000.