Specifications
4 Message Reference
54
dest_stream
The dest_stream references the cross connect switch streams that should be used as a
destination for data. The parameter takes values in the range of 0 to 31.
dest_slot
The dest slot references the timeslot from which to connect or disconnect to the cross
connect switch stream. The dest slot values are in the range of 0 to 127.
4.3.9 MVD_MSG_SC_MULTI_CONNECT - Multiple Connect Request
Synopsis
Message sent to the board to control the switch to connect multiple paths.
Format
MESSAGE HEADER
Field Name
Meaning
type
MVD_MSG_SC_MULTI_CONNECT (0x7e19)
id
0
src
Sending module ID
dst
MVD_module_ID
rsp_req
May be used to request a confirmation.
hclass
0
status
0
err_info
0
len
18
PARAMETER AREA
Offset
Size
Name
0
2
local_stream
2
4
timeslot_mask
6
2
mode
8
2
source_st
10
2
source_ts
12
6
Reserved. Must be set to 0.
Description
This message is sent to the board in order to control the configuration of the cross
connect switch for more complex configurations.
Parameters
The MVD_MSG_SC_MULTI_CONNECT message includes the following parameters:
local_stream
The logical reference of the local stream that the message relates to, that is, 0 to one
less than the number LIUs corresponding to the liu_id.