Specifications

Dialogic
®
DSI SS7MD Network Interface Boards Programmer's Manual Issue 4
53
Value
Meaning
1
Make a simplex connection from a timeslot on the cross connect switch to a timeslot
on the local bus. Use the local_stream, local_slot, source_stream, and source_slot
parameters to specify the local and switch timeslots, respectively.
2
Make a simplex connection from a timeslot on the CPU local bus stream to a
timeslot on the cross connect switch. Use the local_stream, local_slot, dest_stream,
and dest_slot parameters to specify the local and switch timeslots, respectively.
3
Make a duplex connection between a CPU local bus stream timeslot and two cross
connect switch timeslots. Use the local_stream, local_slot, source_stream, and
source_slot parameters to specify one simplex connection; and the local_stream,
local_slot, dest_stream, and dest_slot parameters to specify the other simplex
connection.
4
Remove a simplex connection from a timeslot on the cross connect switch to a
timeslot on the CPU local bus. Use the local_stream and local_slot parameters to
specify the timeslot for disconnection.
5
Remove a simplex connection from a timeslot on the CPU local bus to a timeslot on
the cross connect. Use the local_stream and local_slot parameters to specify the
timeslot for disconnection.
6
Remove a duplex connection between two timeslots on the cross connect switch
and one timeslot on the CPU local bus. Use the local_stream and local_slot
parameters to specify both timeslots for disconnection.
8
Remove a connection between a switch timeslot and a CPU local bus timeslot.
Then create a simplex connection between the same CPU local bus timeslot back to
the switch timeslot. Use the local_stream and local_slot parameters to specify the
CPU local bus timeslot, and the source_stream and source_timeslot to specify the
switch timeslot.
11
Make a simplex connection between two CPU local bus timeslots. The
source_stream and source_slot parameters specify the source of the signal in terms
of liu_id and timeslot, respectively. The local_stream and local_slot parameters
specify the outgoing lLIU or CPU stream and timeslot, respectively.
12
Make a duplex connection between two CPU local bus timeslots. The
source_stream and source_slot parameters specify the source of the signal in terms
of liu_id and timeslot, respectively. The local_stream and local_slot parameters
specify the outgoing liu_id and timeslot, respectively
13
Remove a duplex connection between two CPU local bus timeslots. Use the
local_stream and local_slot parameters to specify one timeslot and the
source_stream and source_slot parameters to specify the other.
source_stream
The source_stream references the cross connect switch streams that should be used as
a source for data. The parameter takes values in the range of 0 to 31. For some modes
(for example, 11 and 12), this field is used to specify a local stream instead of a switch
stream.
source_slot
The source slot references the timeslot from which to connect or disconnect to
the cross connect switch stream. The source slot values are in the range 0 to 127.