Specifications
4 Message Reference
50
Parameters
liu_id
The identifier of the T1/E1/J1 LIU in the range of 0 to one less than the number of
LIUs.
timeslot
The timeslot number of the T1/E1/J1 LIU on which the data from the switch channel
will be transmitted. Valid ranges for T1/J1 are 1 to 24 and for E1 are 1 to 31.
sc_channel
The channel number on the switch to which the LIU will listen. This should be in the
range of 0 to one less than the total number of channels provided by the cross connect
switch.
4.3.7 MVD_MSG_RESETSWX - Reset Switch Request
Synopsis
Resets the digital switch to its default state in accordance with the current board
configuration.
Format
MESSAGE HEADER
Field Name
Meaning
type
MVD_MSG_RESETSWX (0x7e00)
id
0
src
Sending module ID
dst
MVD_module_ID
rsp_req
Used to request a confirmation.
hclass
0
status
0
err_info
0
len
0
Description
This message is sent to the board to reset the state of the digital cross connect switch.
The confirmation message (if requested) indicates success with a status value of 0.
On receipt of the confirmation message, the operation to reset the switch is completed.