Network Card User Manual
Table Of Contents
- Dialogic® DSI SS7MD Network Interface Board Programmer's Manual
- Contents
- Chapter 1: Introduction
- Chapter 2: Specification
- Chapter 3: Installation
- Chapter 4: Dialogic® DSI SS7MD Board Configuration and Operation
- 4.1 Regulatory and Geographic Considerations
- 4.2 System Structure
- 4.3 Running Host Binaries With Dialogic® DSI SS7MD Board
- 4.4 System Configuration
- 4.5 Protocol Configuration
- 4.6 Monitoring
- 4.7 ATM Monitoring
- 4.8 Switching Timeslots between LIUs
- 4.9 Received Message Timestamping
- 4.10 High Speed Link Operation
- 4.11 Operation of the Thermal Sensor
- Chapter 5: Program Execution
- Chapter 6: Message Reference
- Chapter 7: Configuration Command Reference
- 7.1 Physical Interface Configuration Commands
- 7.2 Monitor Configuration Commands
- 7.3 MTP Configuration Commands
- 7.4 ATM Configuration Commands
- 7.5 ISUP Configuration Commands
- 7.6 TUP Configuration Commands
- 7.7 SCCP Configuration Commands
- 7.8 DTC Configuration Commands
- 7.9 TCAP Configuration Commands
- 7.10 MAP Configuration Commands
- 7.11 INAP Configuration Commands
- 7.12 IS41 Configuration Commands
- Chapter 8: Host Utilities
- Appendix A: Protocol Configuration Using Discrete Messages
- Appendix B: Thermal guidelines for selecting suitable servers for use with a Dialogic® DSI SS7MDL4 Network Interface Board
- Glossary
- Index

104
6 Message Reference
6.7.3 SSD_MSG_STATE_IND – Board Status Indication
Synopsis
Message sent to the application on completion of the reset and download sequence or on detection of a
board status event.
Note: This message is not required when using the s7_mgt protocol configuration utility.
Format
Description
This message is used to convey the status of a board reset operation (success of failure) to the user. The
status is indicated in the status field of the message header. The following table shows the possible
event_type values:
• event_type
Parameter
The message parameters are:
• board_type
Set to 16 for SS7MD.
• failure_code
MESSAGE HEADER
Field Name Meaning
type SSD_MSG_STATE_IND (0x06a0)
id board_id
src SSD_module_ID (0x20)
dst mgmt_id for SSD
rsp_req Used to request a confirmation
hclass 0
status event_type (see below)
err_info 0
len 4
PARAMETER AREA
Offset Size Name
0 2 board_type
2 2 failure_code
Value Meaning
0x60 Reset successful
0x62 Board failure
0x66 License validation failure
0x67 License appears corrupt
0x70 Message congestion toward board cleared
0x71 Message congestion toward board onset
Value Meaning
0x0000 undefined
0x00d7 Thermal failure