Specifications
Dialogic
®
DSI SS7HD Network Interface Boards Programmer's Manual Issue 11
87
Description
This message is sent to the board in order to control the configuration of the CT switch
device for more complex configurations.
Parameters
The MVD_MSG_SC_MULTI_CONNECT message includes the following parameters:
local_stream
The logical reference of the local stream that the message relates to, that is, 0 to one
less than the number LIUs corresponding to the liu_id.
timeslot_mask
A 32-bit mask representing up to 32 timeslots on the local stream. Bit 0 corresponds to
timeslot 0. A 1 in the mask indicates that the pattern should be output on this timeslot,
a 0 indicates that it should be left unchanged.
mode
The mode of operation. The following table shows the permitted values and their
meanings.
Value
Description
1
Simplex connection from CT Bus to local stream timeslots
10
Generate the same pattern on multiple local stream timeslots
source_st, source_ts
When mode is set to 1, these parameters give the source stream and timeslot on the
CT Bus for connection to the specified local timeslots.
dest_st, dest_ts
Not currently used in this message. Set to 0.
pattern
The pattern to be generated on the indicated timeslots. Valid data is in the range 0 to
255.