dest_slot
The destination slot references the CT Bus timeslot to which a local stream timeslot
can be connected or disconnected. The destination slot values are in the range 0 to
127.
pattern
The value of the fixed data to be generated. The value should be in the range 0 to 255.
Typical values are:
— 0x2a is the ITU-T idle pattern, and is appropriate for signaling (D)
channel.
— 0x55 is appropriate for A-law bearer channels (0x55 or 0xd5 are A-law
silence).
— 0xff is appropriate for µ-law bearer channels (0xff is µ-law silence).
4.3.10 MVD_MSG_SC_MULTI_CONNECT - CT Bus Multiple Connect
Request
Synopsis
Message sent to the board to control the switch to connect multiple paths through the
CT Bus switch.
Format
MESSAGE HEADER
Field Name
Meaning
type
MVD_MSG_SC_MULTI_CONNECT (0x7e19)
id
0
src
Sending module ID
dst
MVD_module_ID
rsp_req
May be used to request a confirmation.
hclass
0
status
0
err_info
0
len
18
PARAMETER AREA
Offset
Size
Name
0
2
local_stream
2
4
timeslot_mask
6
2
mode
8
2
source_st
10
2
source_ts
12
2
dest_st
14
2
dest_ts
16
2
pattern