Specifications
2 Specification
28
Table 6. Relationship between License Button Codes, Run Modes and Protocol Modules
Buttons
Run
Mode
Run
Mode
Value
Protocol Modules
Monitor
MTP2
MTP3
ISUP
TUP
SCCP
TCAP
MAP
IS41
INAP
No button
DTI
1
BF, BE, BD, BC,
BA
MON
17
Rx Only
BF, BE, BD, BC
MTP2
2
R
BF, BE, BD, BC
MTP
3
R
R
BF, BE, BD
MTP2-L
25
L
BF, BE, BD
MTP-L
29
L
R
BF, BE, BD
ISUP
4
R
R
R
BF, BE, BD
TUP
6
R
R
R
BF, BE, BD
SCCP-
CL
10
R
R
CL
BF, BE, BD
SCCP-
CO
11
R
R
CO
BF, BE, BD
TCAP
12
R
R
R
BF, BE
ISUP-L
5
L
R
L
BF, BE
TUP-L
7
L
R
L
BF, BE
TCAP-L
30
R
R
L
BF, BE
MAP
14
R
R
CL
R
R
BF, BE
IS41
15
R
R
CL
R
R
BF, BE
INAP
21
R
R
CL
R
R
BF
MAP-L
31
L
R
CL
L
L
BF
IS41-L
32
L
R
CL
L
L
BF
INAP-L
33
L
R
CL
L
L
BF
TCAP-
ISUP
13
R
R
R
CL
R
BF
MAP-
ISUP
22
R
R
R
CL
R
R
BF
MAP-
TUP
23
R
R
R
CL
R
R
BF
MAP-
INAP
24
R
R
CL
R
R
R
BF
IS41-
INAP
26
R
R
CL
R
R
R
BF
MAP-
INAP-
ISUP
28
R
R
R
CL
R
R
R
Key:
Rx Only - MTP2 receive only operation
L - Large
R - Regular
CO - Connection-Oriented CL - Connectionless
NOTE: HSL requires the use of a license button that supports the MTP2 “Large”
model, when signaling is used. The following buttons can be used: BF, BE, BD and