Specifications
Dialogic
®
DSI SS7HD Network Interface Boards Programmer's Manual Issue 11
113
Value
Description
0
Configured as CT Bus slave, PLL not used
1
Recovering from LIU specified in liu_rec parameter
5
Local reference oscillator
7
NETREF_1
8
NETREF_2
9
PLL in holdover mode
liu_rec
If the PLL is recovering the clock from a line interface, this parameter indicates the
liu_id (in the range 0 to one less than the number of LIUs) of the LIU being used as a
reference. Otherwise, this parameter should be ignored.