Specifications
Dialogic
®
DSI SS7HD Network Interface Boards Programmer's Manual Issue 11
111
prbs_status
The status of Pseudo Random Bit Sequence (PRBS) indications. Possible values are:
— 1 - PRBS is valid, the counts are correct.
— 2 - PRBS counters have overrun.
— 3 - PRBS sequence is not synchronized.
prbs_error_count
A count of the number of times the PRBS mechanism detected an error.
prbs_bit_count
A count of the bits that the PRBS unit has received. This parameter can be used to
calculate the error rate.
4.6.3 MVD_MSG_R_CLK_STATUS - Clock Status Request
Synopsis
Message sent by the application to read the current clocking state.
Format
MESSAGE HEADER
Field Name
Meaning
type
MVD_MSG_R_CLK_STATUS (0x6e04)
id
0
src
Sending Module ID
dst
MVD_TASK_ID (0x10)
rsp_req
must be used to request a confirmation
hclass
0
status
0
err_info
0
len
10
PARAMETER AREA
Offset
Size
Name
0
2
clk_mode
2
2
status_a
4
2
status_b
6
2
pll_state
8
2
liu_rec