Installation guide
screw at the top of the plate. Keep the blanking
plate for future use
CAUTION: To prevent damage to the board or
computer, care should be taken to ensure correct
alignment of the connector and board guide before
final insertion.
4. Using the board guides in the computer, align the
board with the slot and press the board firmly
until fully seated.
5. Secure the board using the retaining screw at the
top of the end bracket.
6. Use the CT Bus cable to connect the board to
other boards that use the CT Bus. Refer to the
Regulatory Notices document.
7. Replace the cover on the computer and reconnect
the power cable and network connections.
8. Turn on the computer.
6. Connecting to External Equipment
Connecting T1 or E1 Cables
Connect T1 or E1 cables to the Port L1 to Port L4
connectors on the end bracket. Connector pinouts for
the Port L1 to Port L4 connectors are shown in the
following figure.
Note: Cables must be twisted pair, shielded, and
grounded at both ends.
Port L1 to Port L4 Connector Pinouts
Connecting a V.11 Serial Cable
Connect a shielded serial cable to the AUX Port
connector on the end bracket. Both ports are
presented in the same female 26 way high density D-
type connector and use V.11 (V.35 compatible)
electrical interface characteristics.
Note: The ferrite clamp provided must be fitted to
the cable close to the board.
The serial port interface may be clocked either by an
internally generated clock or by an externally applied
clock. In both cases, the same clock is used for both
the transmit data and the receive data.
For internal clock operation, use the transmit clock
pins and make no connection to the receive clock pins
on the connector. For external clock operation
connect the clock source to the receive clock pins on
the connector and make no connection to the
transmit clock pins.
RCV_RING
RCV_TIP
N/C
XMIT_RING
XMIT_TIP
N/C
N/C
N/C
1
2
3
4
5
6
7
8
Pin
Pin 1
Function
V.11 Serial Port Connector Pinouts
7. After Installing the Board
After installing the DSI SPCI2S or DSI SPCI4, refer to
the DSI SPCI Network Interface Boards
Programmer's Manual for software installation and
configuration instructions. Ensure that the
configuration is compliant with all local requirements.
Refer to the DSI SPCI Network Interface Boards
Programmer's Manual for software licensing
instructions.
8. Removing the Board
CAUTION: Components may be hot.
When the board is removed from a system, the board
may contain hot components. To avoid risk of burns,
the board should only be handled by the end bracket
until the components have had time to cool.
Removal of the board is essentially the reverse of the
installation procedure described in Section 5,
Installing the Board, as summarized in Step 1
through Step 6 below:
1. Observe anti-static precautions.
2. Disconnect the telephony cables.
3. Remove the computer’s power cord.
4. Remove the computer’s cover.
5. Remove and set aside the board’s retaining screw.
6. Remove the board and place it in static protective
packaging.
Pin No. Direction Function
1 Chassis ground
2 Output V11 Tx inverted clock Port B
3 Output V11 Tx clock Port B
4 Output V11 Tx inverted data Port B
5 Output V11 Tx true data Port B
6 Input V11 Rx inverted clock Port B
7 Input V11 Rx clock Port B
8 Input V11 Rx inverted data Port B
9 Input V11 Rx true data Port B
10 Signal ground
11 .. 18 Do not connect
19 Output V11 Tx inverted clock Port A
20 Output V11 Tx clock Port A
21 Output V11 Tx inverted data Port A
22 Output V11 Tx true data Port A
23 Input V11 Rx inverted clock Port A
24 Input V11 Rx clock Port A
25 Input V11 Rx inverted data Port A
26 Input V11 Rx true data Port A
9. Warranty and Return Information
Warranty Period
For specific warranty information for this board, refer
to the Warranty section of the Products page, located
at this URL: http://www.dialogic.com/warranties/.
Contacting Technical Support
Dialogic provides technical support for its products
through a network of value added distributors who
are trained to answer technical questions on installing
and configuring Dialogic
®
products. If you are unsure
how to contact your support channel, please call
Dialogic in the United States at 973-967-6600 (9am-
5pm EST) and we will assist in obtaining the
appropriate support channel.
Outside the United States please refer to http://
www.dialogic.com/support/contact to obtain local
contact information. Dialogic also provides direct
support via Dialogic
®
Pro™ Services agreements. For
more details of direct support from Dialogic please
refer to: http://www.dialogic.com/support/
DialogicPro.
Returning a Product
To return a board for warranty repair or any other
returns, refer to the following:
http://www.dialogic.com/support/hwfaults.
10. Sales Assistance
If you have a sales question, please contact your
local Sales Representative or the Regional Sales
Office for your area. Address, telephone and fax
numbers, are available at the Dialogic website
located at: http://www.dialogic.com/contact.htm.
To purchase Dialogic
®
products, please refer to the
following website to locate the appropriate supplier:
http://www.dialogic.com/purchase.htm.
Copyright © 2009 Dialogic Corporation. All Rights Reserved.
You may not reproduce this document in whole or in part
without permission in writing from Dialogic Corporation at the
address provided below.
All contents of this document are furnished for
informational use only and are subject to change
without notice and do not represent a commitment
on the part of Dialogic Corporation or its subsidiaries
(“Dialogic”). Reasonable effort is made to ensure the
accuracy of the information contained in the
document. However, Dialogic does not warrant the
accuracy of this information and cannot accept
responsibility for errors, inaccuracies or omissions
that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN
CONNECTION WITH DIALOGIC
®
PRODUCTS. NO
LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR
OTHERWISE, TO ANY INTELLECTUAL PROPERTY
RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT
AS PROVIDED IN A SIGNED AGREEMENT BETWEEN
YOU AND DIALOGIC, DIALOGIC ASSUMES NO
LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS
ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO
SALE AND/OR USE OF DIALOGIC PRODUCTS
INCLUDING LIABILITY OR WARRANTIES RELATING
TO FITNESS FOR A PARTICULAR PURPOSE,
MERCHANTABILITY, OR INFRINGEMENT OF ANY
INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical,
life saving, life sustaining, critical control or safety
systems, or in nuclear facility applications.
Due to differing national regulations and approval
requirements, certain Dialogic products may be
suitable for use only in specific countries, and thus
may not function properly in other countries. You are
responsible for ensuring that your use of such
products occurs only in the countries where such use
is suitable. For information on specific products,
contact Dialogic Corporation at the address indicated
below or on the web at www.dialogic.com.
It is possible that the use or implementation of any
one of the concepts, applications, or ideas described
in this document, in marketing collateral produced by
or on web pages maintained by Dialogic may infringe
one or more patents or other intellectual property
rights owned by third parties. Dialogic does not
provide any intellectual property licenses with the
sale of Dialogic products other than a license to use
such product in accordance with intellectual property
owned or validly licensed by Dialogic and no such
licenses are provided except pursuant to a signed
agreement with Dialogic. More detailed information
about such intellectual property is available from
Dialogic’s legal department at 9800 Cavendish Blvd.,
5
th
Floor, Montreal, Quebec, Canada H4M 2V9.
Dialogic encourages all users of its products to
procure all necessary intellectual property
licenses required to implement any concepts or
applications and does not condone or
encourage any intellectual property
infringement and disclaims any responsibility
related thereto. These intellectual property
licenses may differ from country to country and
it is the responsibility of those who develop the
concepts or applications to be aware of and
comply with different national license
requirements.
Dialogic, Dialogic Pro, Brooktrout, Diva, Cantata,
SnowShore, Eicon, Eicon Networks, NMS
Communications, NMS (stylized), Eiconcard,
SIPcontrol, Diva ISDN, TruFax, Exnet, EXS, SwitchKit,
N20, Making Innovation Thrive, Connecting to
Growth, Video is the New Voice, Fusion, Vision,
PacketMedia, NaturalAccess, NaturalCallControl,
NaturalConference, NaturalFax and Shiva, among
others as well as related logos, are either registered
trademarks or trademarks of Dialogic Corporation or
its subsidiaries. Dialogic's trademarks may be used
publicly only with permission from Dialogic. Such
permission may only be granted by Dialogic’s legal
department at 9800 Cavendish Blvd., 5th Floor,
Montreal, Quebec, Canada H4M 2V9. Any authorized
use of Dialogic's trademarks will be subject to full
respect of the trademark guidelines published by
Dialogic from time to time and any use of Dialogic’s
trademarks requires proper acknowledgement.
The names of actual companies and products
mentioned herein are the trademarks of their
respective owners.