User`s guide

Dialogic
®
1000 and 2000 Media Gateway Series User’s Guide — September 2007 59
Dialogic Corporation
Parameter Reference
3.4.3 Message Waiting Control Group
The Analog parameters in the Message Waiting Control group include:
MWI Confirmation Tone
Use Same Port for MWI Clear/Set
3.4.3.1 MWI Confirmation Tone
Description: Specifies whether or not the PBX sends a confirmation tone to signal the successful
completion of a Message Waiting Indication (MWI) request.
Allowed Values:
Yes = PBX will send a confirmation tone.
No = PBX will not send a confirmation tone.
Default Value = No
INI File Parameter Name = telMwiConfirm
3.4.3.2 Use Same Port for MWI Clear/Set
Description: Specifies if the PBX requires that the telephony station that set an MWI be used to
clear the MWI.
Note: Some PBX types require that the port that set an MWI be the same port that clears the MWI.
Allowed Values:
Yes = Use the same port to set and clear the MWI.
No = Not necessary to use the same port to clear an MWI that was used to set the MWI.
Default Value = Yes
INI File Parameter Name = telMwiSamePort
3.4.4 CPID Group
The Analog parameters in the Inband CPID group include:
Initial Wait for Inband CPID
Inband CPID Complete Timeout
Analog Interface Type
Central Office (Type I) Caller ID Type
Central Office (Type I) Caller ID Alert Type
Central Office (Type I) FSK Caller ID Expiration
Central Office (Type I) FSK Caller ID Timeout