User`s guide
Dialogic
®
1000 and 2000 Media Gateway Series User’s Guide — September 2007 59
Dialogic Corporation
Parameter Reference
3.4.3 Message Waiting Control Group
The Analog parameters in the Message Waiting Control group include:
• MWI Confirmation Tone
• Use Same Port for MWI Clear/Set
3.4.3.1 MWI Confirmation Tone
Description: Specifies whether or not the PBX sends a confirmation tone to signal the successful
completion of a Message Waiting Indication (MWI) request.
Allowed Values:
• Yes = PBX will send a confirmation tone.
• No = PBX will not send a confirmation tone.
Default Value = No
INI File Parameter Name = telMwiConfirm
3.4.3.2 Use Same Port for MWI Clear/Set
Description: Specifies if the PBX requires that the telephony station that set an MWI be used to
clear the MWI.
Note: Some PBX types require that the port that set an MWI be the same port that clears the MWI.
Allowed Values:
• Yes = Use the same port to set and clear the MWI.
• No = Not necessary to use the same port to clear an MWI that was used to set the MWI.
Default Value = Yes
INI File Parameter Name = telMwiSamePort
3.4.4 CPID Group
The Analog parameters in the Inband CPID group include:
• Initial Wait for Inband CPID
• Inband CPID Complete Timeout
• Analog Interface Type
• Central Office (Type I) Caller ID Type
• Central Office (Type I) Caller ID Alert Type
• Central Office (Type I) FSK Caller ID Expiration
• Central Office (Type I) FSK Caller ID Timeout