User`s guide
54 Dialogic
®
1000 and 2000 Media Gateway Series User’s Guide — September 2007
Dialogic Corporation
Parameter Reference
Allowed Values:
• 1 stop bit
• 2 stop bits
Default Value = 1 stop bit
INI File Parameter Name = sysSerialStopBits
3.3.4 Serial Port, COM2 Group (DMG2000 Only)
The Serial Port, COM2 group parameters are used to configure the DMG2000
diagnostics/administration serial port (COM2 connector). The system parameters in the Serial Port
group include:
• Serial Port Baud Rate
• Serial Port Parity
• Serial Port Data Bits
• Serial Port Stop Bits
3.3.4.1 Serial Port Baud Rate
Description: Specifies the baud rate of the DMG2000 serial port.
Allowed Values:
• 1200 = 1200 bps
• 2400 = 2400 bps
• 9600 = 9600 bps
• 19200 = 19200 bps
• 38400 = 38400 bps
• 57600 = 57600 bps
• 115200 = 115200 bps
Default Value = 115200 bps
INI File Parameter Name = sysSerialBaudRateCom2
3.3.4.2 Serial Port Parity
Description: Specifies the parity of the DMG2000 serial port.
Allowed Values:
• None = Parity will not be used.
• Even = Even parity will be used.
• Odd = Odd parity will be used.