User`s guide
Dialogic
®
1000 and 2000 Media Gateway Series User’s Guide — September 2007 127
Dialogic Corporation
Parameter Reference
Default Value = None
INI File Parameter Name = cpToneEvent
3.11.3 Tone Name
Description: Specifies the text name associated with this tone definition.
Allowed Values: String with length between 0 - 31 characters
Default Value = Empty string
INI File Parameter Name = cpToneName
3.11.4 Cadence Type
Description: Specifies the cadence type for this tone definition.
Allowed Values:
• Continuous = an "on" tone with no "off".
• OnOff = an "on" cadence followed by an "off" cadence.
• OnOffQuick = detection is reported at the end of the "off" period following the first valid "on"
period.
• Alternating = two tones that alternate with no "off" time in between.
• Sequential = one, two or three tones that come in sequence.
Default Value = Continuous
INI File Parameter Name = cpCadenceType
3.11.5 Number of Cadence Cycles
Description: Specifies the number of cadence cycles for this tone definition.
Allowed Values: 1-10
Default Value = 2
INI File Parameter Name = cpCadenceNumCycles
3.11.6 Tone Frequency
Description: Specifies the frequencies for this tone definition. A tone can be described by up to
three (3) frequencies. For Alternating and Sequential Tones, the top frequency is the first frequency,