INI File Parameter Name = h323ProxyAddr
3.8.7 Preferred Gatekeeper ID
Description: Specifies the preferred gatekeeper ID when multiple gatekeepers respond to a
gatekeeper auto-discovery query. Used only when the GateKeeper Mode is Auto.
Allowed Values: Any valid string (0 to 63 characters)
Default Value = (no default value)
INI File Parameter Name = h323GKPreferred
Note: Unit requires a restart if this parameter value is changed.
3.8.8 Fast Start
Description: Specifies if the Fast Start method will be attempted during H.323 call setup.
Allowed Values:
• Yes = Fast Start method is enabled.
• No = Fast Start method is not enabled.
Default Value = Yes
INI File Parameter Name = h323FastStart
Note: H.323 is only supported in Version 5.1 SU1 Software or earlier.
3.8.9 H.245 Signaling User Input
Description: Specifies the format of the User-to-User Input messages that are transported between
the Media Gateway and the VoIP endpoints.
Allowed Values:
• Yes = User-to-User Input messages are sent between the Media Gateway and the VoIP
endpoints using the Signaling format.
• No = User-to-User Input messages are sent between the PBX-I Media Gateway and the VoIP
endpoints using the Alpha/Numeric format.
Default Value = Yes
INI File Parameter Name = h323SignalingUUI