User guide
FAX BOARDS AND FAX DRIVERS INSTALLATION
68
Configuration
Parameters for E1 ISDN
Ports
Asynchronous Balanced Mode Extended (SABME) messages. Set the parameter as
follows:
FALSE = Indicates that the port does not send SABME messages
TRUE = Indicates that the port does send layer 2 SABME messages
Default value: TRUE
screening
Specifies a value that indicates whether the port provides and validates the calling party
number passed to the called party. Valid values are:
NETWORK_PROVIDED Indicates that the network validates the calling party
number.
NONE Indicates that the port does not provide a calling party number to the called
party.
USER_NOT_SCREENED Indicates that the port provides the calling party number
without validating it.
USER_VERIFICATION_FAILED Indicates that the port failed to validate the calling
party number.
USER_VERIFICATION_PASSED Indicates that the port provides the calling party
number and passes a successfully validated number to the called party.
Note: You should set the parameter to USER_NOT_SCREENED when connected to a
public network.
Default value: USER_NOT_SCREENED
send_dialcomplete
Specifies a Boolean value that determines whether the system sends a dial complete
informational element (IE) on outbound calls. Set the parameter as follows:
FALSE = Indicates that the port does not send a dial complete IE message on
outbound calls.
TRUE = Requests the system to send a dial complete IE message on outbound
calls.
Default value: TRUE
switch_type
Specifies a value indicating the type of switch used for the board connection. Valid values
are:
ATT_4ESS AT&T #4 ESS
ATT_5ESS AT&T #5 ESS
NTI_DMS100 Nortel DMS-100
NTI_DMS250 Nortel DMS-250
MD110_T1 Selects Ericsson MD-110 switch for North America
MD110_E1 Selects Ericsson MD-110 switch (International)
SIEMENS Siemens
NTT Japan
UNKNOWN Selects a switch type that complies with the ITU-T standards
Default value: UNKNOWN (ITU-T compliant)