Configuration Parameters
for BRI Ports
Default value: CPE
max_did_digits
Specifies a value that defines the maximum number of DID digits to expect before
accepting an incoming call. Valid values are:
0 = Disables waiting for DID digits
1 - 63 = Specifies the number of digits to expect before accepting an incoming
call
Range: 0 through 63
Default value: 0
msn_x
Specifies a value that allows the application to supply one of a series of multiple
subscriber numbers (MSN) to acknowledge. The parameter allows you to specify up
to 10 different MSN numbers as: msn_x = XXXX where x indicates the series value
from 0 through 9 and
XXXX supplies the multiple subscriber telephone number to associate with the x
value.
When you set one or more of the ten numbers and the port operates in point-to-
multipoint mode, the port only acknowledges incoming calls to a called party that
matches one of the numbered values. If you do not specify a value for this parameter,
the port answers all calls presented to it. If you define less than 10 numbers, use the
lower numbers first (for example: msn_0, msn_1, msn_2, and so on). Valid values
are:
Range: 1 through 15 character string (_ECC_MAX_ANI_LENGTH) to specify the
associated called party number. Specifies the called party number assigned to the
msn_x series number where x is a value from 0 through 9. Use the lower numbers
first for the msn_x series.
Default value: Blank
numbering_plan
Specifies a value that identifies the type of numbering plan used for outbound calls
(called party number). Valid values are:
ISDN = Indicates that the port uses an ISDN numbering plan
PRIVATE = Indicates that the port uses a private numbering plan
TELEPHONY = Indicates that the port uses a telephony numbering plan
UNKNOWN = Indicates that the port uses an unknown numbering plan
Default value: UNKNOWN
numbering_type
Specifies a value that identifies the type of telephone number used for outbound calls
(called party number). Valid values are:
ABBREVIATED = Indicates that the port uses an abbreviated numbering type
INTERNATIONAL = Indicates that the port uses an international numbering
type
NATIONAL = Indicates that the port uses a national numbering type
SUBSCRIBER = Indicates that the port uses a subscriber numbering type
UNKNOWN = Indicates that the port uses an unknown numbering type
Default value: UNKNOWN