User guide
BROOKTROUT CONFIGURATION FILES
57
Clock Configuration
Parameters
TrunkB = The network trunk, port B.
TrunkC = The network trunk, port C.
TrunkD = The network trunk, port D.
TrunkE = The network trunk, port E.
TrunkF = The network trunk, port F.
TrunkG = The network trunk, port G.
TrunkH = The network trunk, port H.
Netref1 = The H.100/H.110 network reference (1) clock.
Netref2 = The H.100/H.110 network reference (2) clock.
clock_a = The H.100/H.110 A clock.
clock_b = The H.100/H.110 B clock.
Default value: TrunkA
Port Configuration
Parameters
port_config
Specifies one of the following values that defines the CT bus or line type to configure for
the port.
INACTIVE = Disabled port
ANALOG = Analog line
BRI = Basic Rate Interface
T1_ISDN = T1 ISDN
T1_ROBBED_BIT = T1 RBS
E1_ISDN = E1 ISDN
E1_R2_CAS = E1 R2 CAS
E1_CAS = E1 CAS (not supported in this release)
E1_DPNSS = E1 DPNSS (not supported in this release)
Default value: INACTIVE
fractional_start_channel
Specifies the zero-based index value of the first channel available on the port. If you do
not specify this parameter, the API assumes that the full port is available. When you
configure a fractional port, the auto_connect feature only connects the channels in use.
The valid values are:
0 - 29 = E1 (all types)
0 - 22 = T1 ISDN
0 - 23 = T1 RBS
Range: 0 - 29
Default value: 0
fractional_channel_count
Specifies a value that indicates the number of channels available on the fractional port.