User guide

FAX BOARDS AND FAX DRIVERS INSTALLATION
56
Global options
Each of these lines begins with the keyword connect, and is followed in order by the connection
mode, source port class, unit, stream, and slot, and the destination port class, unit, stream, and
slot. The meanings of these values follow. If you use this parameter to specify connections, the
call control ignores any value set in the auto_connect parameter.
conn_mode
Specifies the relationship between the source (S) and destination (D) ports with one of the
following values. The value 7 is normally used.
1 = Transmit only
2 = Receive only
3 = Full duplex
7 = Full duplex with signaling
9 = Transmit only, SD inverted
A = Receive only, SD inverted
B = Full duplex, SD inverted
F = Full duplex with signaling, SD inverted
src_port_class
Specifies the source telephony resource port class. Specify the value in hexadecimal.
0 = Channel
E = Bus (for example, H.100)
F = Network (T1 or E1)
src_port_unit
Specifies the source resource port unit number for the source port class. If the class is 0
(channel), then the port unit value indicates the logical channel number. (When using Bfv Line
Attach, the API sets the ordinal channel value to n - 2 where n is the logical channel number.)
Clock Configuration
Parameters
clock_mode
Specifies a value that determines whether the module drives the clock on the CT bus or
receives its clocking from the CT bus. Valid values are:
MASTER = Configures the module to drive the clock on the CT bus.
SLAVE = Configures the module to receive clocking from the CT bus.
SECOND_MASTER = Use as master if master clock fails. Until the master clock
fails, this module receives clocking from the CT bus.
Default value: MASTER
clock_source
Specifies the source of the clock used to drive the CT bus. Set this parameter only if you
set the value for clock_mode to master. The module derives its clock from:
Internal= The internal oscillator.
TrunkA = The network trunk, port A.