Then expand the IP Call Control Modules node in the tree view, and select H.323. In the right pane, open the
IP Parameters tab, and enter the default gateway as shown below:
5. (if you selected SIP in the IP Stack dialog box) To configure the Brooktrout SIP stack, expand the Call Control
Parameters node in the tree view, click the SR140 item (e.g. Module 0x41: SR140), open the Parameters tab
in the right pane, select SIP in the IP Call Control Module combo box, and select the IP Interface to use as
shown below: