User`s guide

158 Dialogic
®
1000 and 2000 Media Gateway Series User’s Guide
Parameter Reference
3.17.1 Tone Generation Configuration Parameters
3.17.1.1 Call Progress Tone Generation Event
Description: The Tone event or type. The tone will be interpreted as this type of call progress tone
generation.
Allowed Values: The configurable tone events are Dialtone, Busy, Ringback, Congestion, Error,
Disconnect, Intercept, Reorder, and Special.
INI File Parameter Name = cpGenToneEvent
Note: This is a *.ini file parameter only.
3.17.1.2 Call Progress Tone Generation Name
Description: A text string that describes the generation tone.
Allowed Values: String with length between 0 - 31 characters
INI File Parameter Name = cpGenToneName
Note: This is a *.ini file parameter only.
3.17.1.3 Call Progress Tone Generation Num Cadence Cycles
Description: The number of cycles to play the tone.
Allowed Values: Number between 0 - 255.
INI File Parameter Name = cpGenToneNumCycles
Note: This is a *.ini file parameter only.
3.17.1.4 Call Progress Tone Generation Frequency 1 (Hz)
Description: Frequency 1 contained within the tone.
Allowed Values: Number between 0 – 3000. A value of 0 means to ignore the entry.
INI File Parameter Name = cpGenToneFreqHz1
Note: This is a *.ini file parameter only.