User`s guide
156 Dialogic
®
1000 and 2000 Media Gateway Series User’s Guide
Parameter Reference
3.17.0.4 Cadence Type
Description: Specifies the cadence type for this tone definition.
Allowed Values:
• Continuous = an “on” tone with no “off”
• OnOff = an “on” cadence followed by an “off” cadence
• OnOffQuick = detection is reported at the end of the “off” period following the first valid “on”
period
• Alternating = two tones that alternate with no “off” time in between
• Sequential = one, two or three tones that come in sequence
Default Value = Continuous
INI File Parameter Name = cpCadenceType
3.17.0.5 Number of Cadence Cycles
Description: Specifies the number of cadence cycles for this tone definition.
Allowed Values: 1-10
Default Value = 2
INI File Parameter Name = cpCadenceNumCycles
3.17.0.6 Tone Frequency
Description: Specifies the frequencies for this tone definition. A tone can be described by up to
three (3) frequencies. For Alternating and Sequential Tones, the top frequency is the first frequency,
the middle frequency is the second frequency, and the bottom frequency is the third frequency. A
value of 0 means to ignore the entry.
Allowed Values: 0-2000 Hz
Default Value = 0
INI File Parameter Name = cpToneFreq