Service manual
5750-212
Revision A
Page 45
I.V./700 Tubing Kit 5750-125N
Contents
1 Quick-Disconnect Female Inline Fitting [F] 5750-214
2 Quick-Disconnect Male Fitting [C] & [G] 5750-213
1 Tubing, 0.25-inch OD, 24 inches [D]
Tools & Materials
Utility Knife & Clean Wipes
Safety Goggles
[A]
[B]
[C]
[D]
[A]
[B]
[C]
Typical Installation
This tubing kit enables you to replace a damaged
ink line segment between an I.V./700 controller
and an I.V./700 printhead. The illustration above
shows a typical installation.
Installation Notes
_Unscrew the ink can from the controller and set
aside before starting the ink line replacement.
_Before cutting away damaged tubing, depress the
nipple end of the original male quick-disconnect
fitting to bleed ink from the tubing.
Warning: This ink pressure can be up to
90 PSIG (6.2 Bar). Exercise Caution!
_Wrap a clean wipe around the original ink line
before cutting to absorb spilled ink.
_Use a sharp blade such as a single-sided razor
blade, utility knife or diagonal side cutters to make
a clean cut in the replacement tubing. Avoid
crimping the tubing when cutting.
_Loosen the nut on the fitting. Slip the tubing
over the barbed end of the fitting. Tighten the nut
until it comes to a stop.
_Exercise caution when pressurizing the tubing for
the first time.
[A] Original ink line.
[B] Replacement female quick-disconnect fitting.
[C] Replacement male quick-disconnect fitting.
[D] Replacement ink line cut to desired length
from the 24 inches of tubing provided in
this kit.
[B] [C]
[C]
[D]