Data Sheet

www. vkelcom.com
15
VK2828U7G5LF DataSheet
V.KEL Communications Equipment(SHENZHENCo., Ltd
VK-162 说明书
深圳市微科通讯设备有限公司
V1.0
G-M OUS E
Set baud rate to 38400
b5 62 06 00 14 00 01 00 00 00 d0 08 00 00 00 96 00 00 07 00 07 00 00 00 00 00 97 a8
Set baud rate to 115200
b5 62 06 00 14 00 01 00 00 00 d0 08 00 00 00 c2 01 00 07 00 07 00 00 00 00 00 c4 96 b5 62 06 00 01 00 01 08 22
8.4 Set Outputting Rate
1HZ (1 output per second)
B5 62 06 08 06 00 E8 03 01 00 01 00 01 39
5Hz (5 outputs per second)
B5 62 06 08 06 00 C8 00 01 00 01 00 DE 6A B5 62 06 08 00 00 0E 30
10Hz (10 outputs per second)
B5 62 06 08 06 00 64 00 01 00 01 00 7A 12 B5 62 06 08 00 00 0E 30
0.33Hz (1 output per 3 seconds)
B5 62 06 08 06 00 B8 0B 01 00 01 00 D9 41 B5 62 06 08 00 00 0E 30
0.2Hz (1 output per 5 seconds)
B5 62 06 08 06 00 88 13 01 00 01 00 B1 49 B5 62 06 08 00 00 0E 30
0.1Hz (1 output per 10 seconds)
B5 62 06 08 06 00 10 27 01 00 01 00 4D DD B5 62 06 08 00 00 0E 30
0.05Hz (1 output per 20 seconds)
B5 62 06 08 06 00 20 4E 01 00 01 00 84 00 B5 62 06 08 00 00 0E 30
8.5 Other Settings
Reset
B5 62 06 04 04 00 FF 87 01 00 95 F7
Cold Start
B5 62 06 04 04 00 FF FF 02 00 0E 61
Hot Start
B5 62 06 04 04 00 00 00 02 00 10 68
Reset to Manufacturer Defaults
B5 62 06 09 0D 00 FF FF 00 00 00 00 00 00 FF FF 00 00 07 1F 9E
Enable the Sleeping Mode(Low Consumption Mode)
B5 62 06 04 04 00 00 00 08 00 16 74
Note: There is no data outputting in sleeping mode, but the module still keeps positioning. You can send the
Hot Start commands to enable the real-time tracking mode.
Save the changes
B5 62 06 09 0D 00 00 00 00 00 FF FF 00 00 00 00 00 00 17 31 BF