3 ELECTRICAL SPECIFICATIONS
3.1 ELECTRICAL CHARACTERISTICS
Default conditions of 25 °C and 1.8V supply voltage apply to values in Table 5, unless otherwise stated.
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
COMMENTS
Supply voltage
V
DD
1.71
1.8
1.89
V
Power-up/down level
V
POR
Static power supply
1.0
1.25
1.5
V
Supply Ramp Time
T
RAMP
Monotonic ramp. Ramp rate
is 10% to 90% of the final
value
0.01
100
ms
Supply current
I
DD
Idle state
-
1.0
2.5
µA
Measurement
-
210
300
µA
Current consumption while
sensor is measuring.
Average
-
1.3
-
µA
Current consumption in
continuous operation @ 1 Hz
ODR in LP Mode
-
5.2
-
µA
Current consumption in
continuous operation @1 Hz
ODR in LN Mode
Low level input voltage
V
IL
0
-
0.3 V
DD
V
High level input voltage
V
IH
0.7 V
DD
-
V
DD
V
Low level output voltage
V
OL
0 < IOL < 3 mA
-
-
0.2 V
DD
V
Output Sink Current
I
OL
V
OL
= 0.4V
3.1
4.1
-
mA
V
OL
= 0.6V
3.5
4.5
-
mA
Table 5. Electrical Specifications