Datasheet

ICP-10111
High Accuracy, Low Power, Barometric Pressure
and Temperature Sensor IC
InvenSense reserves the right to change the detail
specifications as may be required to permit
improvements in the design of its products.
InvenSense, a TDK Group Company
1745 Technology Drive, San Jose, CA 95110 U.S.A
+1(408) 9887339
invensense.tdk.com
Document Number: DS-000177
Revision: 1.3
Release Date: 05/03/2021
GENERAL INFORMATION
The ICP-10111 pressure sensor family is based on MEMS
capacitive technology which provides ultra-low noise at the
lowest power, enabling industry leading relative accuracy,
sensor throughput, and temperature stability. The pressure
sensor can measure pressure differences with an accuracy of
±1 Pa, enabling altitude measurement differentials as small as
8.5 cm, less than the height of a single stair step.
Consuming only 1.3 µA @1 Hz, available in footprint of 2 mm
x 2.5 mm x 0.92 mm, the ICP-10111 is ideally suited for
mobile phones, wearable fitness monitoring, drones, and
battery powered IoT.
The ICP-10111 offers an industry leading temperature
coefficient offset of ±0.5 Pa/C. The combination of high
accuracy, low power, temperature stability, waterproofing in
a small footprint enables higher performance barometric
pressure sensing for sports activity identification, mobile
indoor/outdoor navigation, and altitude-hold in drones.
DEVICE INFORMATION
PART
NUMBER
PACKAGE
LID OPENING
ICP-10111*
2x2.5x0.92mm
LGA-8L
1-Hole
* Denotes RoHS and Green-Compliant Package
** Moisture Sensitivity Level of the package
APPLICATIONS
Altitude Control of Drones and Flying Toys
Mobile Phones
Virtual Reality and Gaming Equipment
Indoor/Outdoor Navigation (dead-reckoning,
floor/elevator/step detection)
Vertical velocity monitoring
Leisure, Sports, and Fitness Activity Identification
Weather Forecasting
FEATURES
Pressure operating range: 30 to 110 kPa
Noise and current consumption
o 0.4 Pa @ 10.4 µA (ULN mode)
o 0.8 Pa @ 5.2 µA (LN mode)
o 3.2 Pa @ 1.3 µA (LP mode)
Pressure Sensor Relative Accuracy: ±1 Pa for any
10 hPa change over 950 hPa-1050 hPa at 25C
Pressure Sensor Absolute Accuracy: ±1 hPa over
950 hPa-1050 hPa, 0C to 65C
Pressure Sensor Temperature Coefficient Offset:
±0.5 Pa/C over 25C to 45C at 100 kPa
Temperature Sensor Absolute Accuracy: ±0.4C
Temperature operating range: -40 °C to 85 °C
Host Interface: I
2
C at up to 400 kHz
Single Supply voltage: 1.8V ±5%
RoHS and Green compliant
1-Hole Lid Opening
ICP-10111
BLOCK DIAGRAM
VDD
GND
VDD
100nf
GND
GND
SCL
SDA
VDD
VDD
ICP-10111
MCU/HUB/AP
I2C

Summary of content (31 pages)