3 Absolute Maximum Ratings
Table 2: Absolute Maximum Ratings
Symbol
Parameter
Min
Max
Units
Comments
Electrical Parameters
V
DD
Supply Voltage
-0.3
1.98
V
V
DDIO
I/O Interface Supply
-0.3
3.6
V
V
IO1
MOSI/SDA, SCLK/SCL
-0.3
3.6
V
V
IO2
MISO/ADDR, INTn, CSn
-0.3
V
DDIO
+0.3
V
V
SS
Input Ground
-0.3
0.3
V
I
SCR
Input Current (latch-up
immunity)
± 100
mA
AEC-Q100-004
Electrostatic Discharge
ESD
HBM
Electrostatic Discharge HBM
± 2000
V
JS-001-2014
ESD
CDM
Electrostatic Discharge CDM
± 750
V
JS-002-2014
Operating and Storage Conditions
MSL
Moisture Sensitivity Level
1
Unlimited floor lifetime
T
BODY
Max. Package Body
Temperature
260
°C
IPC/JEDEC J-STD-020
T
STRG
Storage Temperature
-40
125
°C
RH
STRG
Storage Relative Humidity
5
95
%
Non-condensing
T
AMB
1
Operating Ambient
Temperature
-40
85
°C
RH
AMB
1
Operating Ambient Rel.
Humidity
5
95
%
Non-condensing
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage
to the device. These are stress ratings only. Functional operation of the device at these or
any other conditions beyond those indicated under Electrical Characteristics is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect device
reliability and lifetime.
Important Note: The ENS160 is not designed for use in safety-critical or life-protecting
applications.