Datasheet

Data Sheet
Power circuit and measurement circuit
Parameter Symbol Typ Min Max Unit
Heating power P
H
76 71 81 mW
Heating voltage V
H
2.4 - - V
Heating current I
H
32 - - mA
Heating resistance
at nominal power
R
H
74 66 82
Rating Symbol Value / Range Unit
Maximum heater power dissipation P
H
88 mW
Maximum sensitive layer power dissipation Ps 8 mW
Voltage supplyHeating current Vsupply 4.9 – 5.1 V
Relative humidity range RH 5 – 95 %RH
Ambient operating temperature Tamb -30 – 85 °C
Storage temperature range Tsto -40 – 120 °C
Storage humidity range RHsto 5 - 95 %RH
MiCS-5524
1084 rev 8
MiCS-5524 with measurement circuit (top view)
The voltage measured on the load resistor is directly linked
to the resistance of the sensor respectively. RLOAD must be
820 at the lowest in order not to damage the sensitive
layer.
MiCS-5524 with recommended supply circuit (top view)
R is a 82 . This resistor is necessary to obtain the right
temperature on the heater while using a single 5V power
supply. The resulting voltage is typically VH = 2.4V.
Page 3 of 5