Fermion TMF8801 ToF Distance Ranging Sensor (20-2500mm) - Datasheet

Table Of Contents
Document Feedback
TMF8801
Typical Operating Characteristics
Datasheet PUBLIC
DS000648 v8-00 • 2021-Jul-08
69 10
6 Typical Operating Characteristics
Following operating characteristics are measured with calibrated devices with full optical stack
including glass and IR ink with >90 % transmissivity. The airgap is set to 0.38 mm. The ambient light is
measured on the 1 m x 1 m target. A very diffuse scotch magic tape 810 is used for measurement with
smudge.
Figure 7:
350 Lux Fluorescent Light and 18% Grey Card
Figure 8:
350 Lux Fluorescent Light, 18% Grey Card and Smudge on Glass
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500
350Lux Fluorescent Light, Grey Card
Measured Distance vs. Target Distance [mm]
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500
350Lux Fluorescent Light, Smudge on glass (1 layer scotch magic tape
810), Grey Card, Measured Distance vs. Target Distance [mm]