Datasheet
Table Of Contents
- General Description
- Pin Assignments
- Absolute Maximum Ratings
- Electrical Characteristics
- Typical Operating Characteristics
- Detailed Description
- Register Description
- Application Information
- Package Information
- Tape & Reel Information
- Soldering & Storage Information
- Laser Eye Safety
- Ordering & Contact Information
- RoHS Compliant & ams Green Statement
- Copyrights & Disclaimer
- Document Status
- Revision Information
- Content Guide
Page 36 ams Datasheet
Document Feedback [v1-08] 2020-Jun-29
TMF8701 − Register Description
Figure 71:
OBJECT_HITS_2 Register
Figure 72:
OBJECT_HITS_3 Register
Calibration and Algorithm State Data Exchange
These registers shall be pre-loaded by the host before
command=0x02 or 0x0B is executed
Figure 73:
FACTORY_CALIB_0 Register
Figure 74:
FACTORY_CALIB_1 Register
0x39: OBJECT_HITS_2
Field Name Reset Type Description
7:0 object_hits[23:16] 0 RO
Sum of the reference SPADs hits during the
distance measurement; zero if no object is
detected or distance algorithm is no used
0x3a: OBJECT_HITS_3
Field Name Reset Type Description
7:0 object_hits[31:24] 0 RO
Sum of the reference SPADs hits during the
distance measurement; zero if no object is
detected or distance algorithm is no used
0x20: FACTORY_CALIB_0
Field Name Reset Type Description
7:0 factory_calib_0 0 RW
Factory calibration data
bits[3:0] are format revision
bits[7:4] are bits [3:0] of crosstalk measurement
0x21: FACTORY_CALIB_1
Field Name Reset Type Description
7:0 factory_calib_1 0 RW
Factory calibration data
bits[11:4] of crosstalk measurement