Datasheet
Table Of Contents
- General Description
- Pin Assignments
- Absolute Maximum Ratings
- Electrical Characteristics
- Typical Operating Characteristics
- Detailed Description
- Register Description
- Application Information
- Package Information
- Tape & Reel Information
- Soldering & Storage Information
- Laser Eye Safety
- Ordering & Contact Information
- RoHS Compliant & ams Green Statement
- Copyrights & Disclaimer
- Document Status
- Revision Information
- Content Guide
ams Datasheet Page 23
[v1-08] 2020-Jun-29 Document Feedback
TMF8701 − Register Description
Figure 39:
COMMAND Register
0x10: COMMAND
Field Name Reset Type Description
7:0 Command 0 RW
Direct the device to control or select contents of the registers from
0x20...0xDF
Setting Meaning
0x00 No command
0x02
Set flag to perform distance or proximity measurement
with 8 bytes of data containing where including setting of
calibration (and algorithm state) configuration.
cmd_data7 = Bit mask which calibration/state data was
downloaded from the host to TMF8701 prior to setting
this command:
Bit 0 - dataFactoryCal: when 1 data from register 0x20
onward includes factory calibration
Bit 1 - dataAlgState: if set, also set dataFactoryCal=1. Data
from register 0x20 onwards includes factory calibration
and algorithm state.
cmd_data6… cmd_data0 : Identical to command=0x03.